Page 19 - Electrician 1st year - TP - Kannada
P. 19

40. Determine direction of induced emf   Electrostatics: Capacitor- Differ-
                                                  and current. (03hrs.)             ent  types,  functions,  grouping
                                                                                    and uses. (08 hrs.)
                                               41. Practice on generation of mutually
                                                  induced emf. (03hrs.)
                                               42. Measure the resistance, impedance
                                                  and determine inductance of choke
                                                  coils  in  different  combinations.
                                                  (05Hrs.)
                                               43. Identify various types of capacitors,
                                                  charging / discharging and testing.
                                                  (05 Hrs.)
                                               44. Group the given capacitors to get
                                                  the required capacity and voltage
                                                  rating. (05 Hrs.)
                                               45. Measure current, voltage and PF and   Inductive  and  capacitive  reac-
                                                 determine the characteristics of RL,   tance, their effect on AC circuit and
                                                 RC and RLC in AC series circuits.   related vector concepts.
                                                 (06Hrs.)
                                               46. Measure  the  resonance  frequency   Comparison  and Advantages  of
                                                 in AC series circuit and determine its   DC and AC systems.
                                                 effect on the circuit. (05hrs.)   Related terms frequency, Instanta-
                                               47. Measure current, voltage and PF and  neous value, R.M.S. value Average
                                                 determine the characteristics of RL,  value,  Peak  factor,  form  factor,
                                                 RC and RLC in AC parallel circuits.  power factor and Impedance etc.
                                                 (06Hrs.)                          Sine wave, phase and phase dif-
                                               48. Measure the resonance frequency in  ference.
                                                 AC parallel circuit and determine its
                                                 effects on the circuit. (05hrs.)   Active and Reactive power.
                                               49. Measure power, energy for lagging   Single  Phase  and  three-phase
                                                 and leading power factors in single   system.
                                                 phase circuits and compare charac-  Problems on A.C. circuits. (10 hrs.)
                                                 teristic graphically.  (06Hrs.)
                                               50. Measure Current, voltage, power, en-
                                                 ergy and power factor in three phase
                                                 circuits. (05hrs.)
                                               51. Practice improvement of PF by use
                                                 of capacitor in three phase circuit.
                                                 (03Hrs.)
                                              52. Ascertain use of neutral by identifying     Advantages  of AC  poly-phase
                                                 wires of a 3-phase 4 wire system and   system.
                                                 find the phase sequence using phase
                                                 sequence meter. (07Hrs.)          Concept of three-phase Star and
                                              53. Determine  effect  of  broken  neutral   Delta connection.
                                                 wire in three phase four wire system.  Line and phase voltage, current
                                                 (04hrs.)                          and power in a 3 phase circuits
                                              54. Determine the relationship between   with  balanced  and  unbalanced
                                                 Line and Phase values for star and   load.
                                                 delta connections. (07Hrs.)       Phase sequence meter. (10 hrs.)
                                              55. Measure the Power of three phase
                                                 circuit for balanced and unbalanced
                                                 loads. (10Hrs.)
                                              56. Measure current and voltage of two
                                                 phases in case of one phase is short-
                                                 circuited in three phase four wire sys-
                                                 tem and compare with healthy system.
                                                 (07hrs.)

                                                             (xvii)
   14   15   16   17   18   19   20   21   22   23   24