+¦ªÉÉºÉ ºÉÆ.                                +¦ªÉÉºÉ Eäò ¶ÉÒ¹ÉÇEò                            {ÉÞ¹`öõ ºÉÆ.

                           (Group the given capacitors to get the required capacity and voltage rating)        99

                           ¨ÉÉb÷¬Ú±É  5 : AC ºÉÌEò]õºÉ (AC Circuits)

                 1.5.45    Eò®úx]õ, ´ÉÉä±]äõVÉ +Éè®ú {ÉÉ´É®ú ¡èòC]õ®ú ¨ÉÉ{ÉxÉÉ +Éè®ú RL, R-C, R-L-C EòÉ AC ºÉÒ®úÒVÉ ºÉÌEò]õ ¨Éå ʴɶÉä¹ÉiÉɪÉÉå EòÉä
                           YÉÉiÉ Eò®úxÉÉ (Measure current, voltage and PF and determine the characteristics of the
                           RL, R-C, R-L-C in AC series circuits)                                              102

                 1.5.46    AC ºÉÒ®úÒVÉ ºÉÌEò]ÂõºÉ ¨Éå ®äúºÉÉäxÉäxºÉ £òÒC´ÉåºÉÒ EòÉä ¨ÉÉ{ÉxÉÉ +Éè®ú ºÉÌEò]õ ¨Éå <ºÉEòÉ |ɦÉÉ´É VÉÉxÉxÉÉ (Measure the
                           resonance frequency in AC series circuit and determine its eff ect on the circuit)   107
                 1.5.47    AC ºÉ¨ÉÉxÉÉxiÉ®ú ºÉÌEò]õºÉ ¨Éå Eò®úx]õ, ´ÉÉä±]äõVÉ +Éè®ú {ÉÉ´É®ú ¡èòC]õ®ú ¨ÉÉ{ÉxÉÉ +Éè®ú R-L, R-C +Éè®ú R-L-C EòÒ
                           ʴɶÉä¹ÉiÉɪÉÉå EòÉ +vªÉªÉxÉ Eò®úxÉÉ (Measure current, voltage and PF and determine the
                           charactertics of R-L, R-C and R-L-C in AC parallel circuits)                       109
                 1.5.48    AC {Éè®äú±É±É ºÉÌEò]õ ¨Éå ®èúVÉÉäxÉäxºÉ £òÒC´ÉåºÉÒ EòÉä ¨ÉÉ{ÉxÉÉ +Éè®ú ºÉÌEò]õ ¨Éå |ɦÉÉ´É EòÉä VÉÉxÉxÉÉ (Measure the
                           resonance frequency in AC parallel circuit and determine its eff ects on the circuit)   112
                 1.5.49    ˺ÉMÉ±É ¡äòVÉ ºÉÌEò] ¨Éå {ÉÉ´É®, BxÉVÉÔ EòÉä ±ÉèËMÉMÉ +Éè® ±ÉÒËbMÉ {ÉÉ´É® ¡èòC]® Eäò ʱÉB ¨ÉÉ{ÉxÉ +Éè® Ê´É¶Éä¹ÉiÉÉ+ÉäÆ EòÒ
                           OÉÉÊ¡òEò °ò{É ºÉä iÉÖ±ÉxÉÉ  (Measure power, energy for lagging and leading power factors in
                           single phase circuits and compare the characteristics graphically)                 113

                 1.5.50    3 ¡äòVÉ ºÉÌEò]õºÉ ¨Éå Eò®Æú]õ, ´ÉÉä±]äõVÉ, {ÉÉ´É®ú, >ðVÉÉÇ +Éè®ú {ÉÉ´É®ú ¡èòC]õ®ú EòÉä ¨ÉÉ{ÉxÉÉ (Measure current, voltage,
                           power, energy and power factor (PF) in 3 phase circuits)                           117
                 1.5.51    iÉÒxÉ ¡äòºÉ ºÉÌEò]õ ¨Éå Eèò{ÉäʺÉ]õ®ú Eäò |ɪÉÉäMÉ ºÉä {ÉÉ´É®ú ¡èòC]õ®ú EòÉä ºÉÖvÉÉ®úxÉä EòÉ +¦ªÉÉºÉ (Practice improvement of
                           PF by use of capacitor in three phase circuit)                                     119
                 1.5.52    iÉÒxÉ ¡äòVÉ, SÉÉ®ú iÉÉ®ú |ÉhÉɱÉÒ ¨Éå xªÉÚ]Åõ±É EòÉ {ÉiÉÉ ±ÉMÉÉxÉÉ +Éè®ú ¡äòVÉ ºÉÒC´ÉäxºÉ ¨ÉÒ]õ®ú EòÉ |ɪÉÉäMÉ Eò®úEäò ¡äòVÉ ºÉÒC´ÉåäºÉ
                           EòÉ {ÉiÉÉ Eò®úxÉÉ (Ascertain use of neutral by identifying wires of a 3-phase 4 wire system and
                           fi nd the phase sequence using phase sequence meter)                                121
                 1.5.53    iÉÒxÉ ¡äòVÉ SÉÉ®ú iÉÉ®ú |ÉhÉɱÉÒ ¨Éå xªÉÚ]Åõ±É iÉÉ®ú Eäò ]Úõ]õxÉä Eäò |ɦÉÉ´É EòÉä YÉÉiÉ Eò®úxÉÉ (Determine eff ect of broken
                           neutral wire in three phase four wire system)                                      123
                 1.5.54    º]õÉ®ú +Éè®ú bä÷±]õÉ EòxÉäC¶ÉxÉ Eäò ʱÉB ±ÉÉ<xÉ +Éè®ú ¡äòVÉ ¨ÉÉxÉÉä Eäò ¤ÉÒSÉ ºÉ¨¤ÉxvÉ EòÉä YÉÉiÉ Eò®úxÉÉ (Determine the
                           relationship between Line and Phase values for star and delta connections)         124

                 1.5.55    ºÉÆiÉÖʱÉiÉ +Éè®ú +ºÉÆiÉÖʱÉiÉ ±ÉÉäb÷ Eäò ʱÉB 3 ¡äòVÉ ºÉÌEò]õ EòÒ {ÉÉì´É®ú EòÉä ¨ÉÉ{ÉxÉÉ (Measure the power of 3-phase
                           circuit for balanced and unbalanced loads)                                         126

                 1.5.56    iÉÒxÉ ¡äòVÉ SÉÉ®ú iÉÉ®ú |ÉhÉɱÉÒ ¨Éå nùÉä ¡äòVÉ EòÉ Eò®Æú]õ +Éè®ú ´ÉÉä±]äõVÉ YÉÉiÉ Eò®úxÉÉ VÉ¤É BEò ¡äòVÉ ¶ÉÉ]Çõ ºÉÌEò]õ ½þÉä +Éè®ú
                           ºÉÖoùgø |ÉhÉɱÉÒ ºÉä iÉÖ±ÉxÉÉ Eò®úxÉÉ (Measure current and voltage of two phases in case of one phase
                           is short-circuited in three phase four wire system and compare with healthy system)   128

                           ¨ÉÉb÷¬Ú±É  6 : ºÉä±É +Éè®ú ¤Éä]ÅõÒ (Cells and Batteries)

                 1.6.57    Ê´ÉʦÉzÉ |ÉEòÉ®ú Eäò ºÉä±ÉÉå EòÉ ={ɪÉÉäMÉ (Use of various types of cell)          129
                 1.6.58    Ê´ÉʦÉzÉ ÎºlÉÊiɪÉÉå ¨Éå ʴɶÉä¹É ´ÉÉä±]äõVÉ +Éè®ú Eò®Æú]õ |ÉÉ{iÉ Eò®úxÉä ½äþiÉÚ ºÉä±ÉÉå Eäò ºÉ¨ÉÚ½þxÉ EòÉ +¦ªÉÉºÉ Eò®úxÉÉ (Practice on
                           grouping of cells for specifi ed voltage and current under diff erent conditions and care)   131

                 1.6.59    ¤Éè]®Ò SÉÉÍVÉMÉ +Éè® SÉÉÍVÉMÉ ºÉÌEò] EòÉ Ê´É´É®hÉ iÉèªÉÉ® Eò®xÉÉ +Éè® +¦ªÉÉºÉ Eò®xÉÉ (Prepare and practice on
                           battery charging and details on charging circuit)                                  133

                 1.6.60    ¤ÉèÊ]ÅõªÉÉå EòÉ ÊxɪÉʨÉiÉ +xÉÖ®úIÉhÉ/¨É®ú¨¨ÉiÉ B´ÉÆ VÉÉÄSÉ EòÉ +¦ªÉÉºÉ (Practice on routine, care / maintenance
                           and testing of batteries)                                                          136
                 1.6.61    +ɴɶªÉEòú ¶ÉÊHò |ÉÉ{iÉ Eò®úxÉä ½äþiÉÚ ¸ÉähÉÒ /ú ºÉ¨ÉÉxiÉ®ú ºÉƪÉÉäVÉxÉ ¨Éå ºÉÉä±É®ú ºÉè±É EòÒ ºÉÆJªÉÉ ÊxÉvÉÉÇÊ®úiÉ Eò®úxÉÉ
                           (Determine the number of solar cells in series / Parallel for given power requirement)   138