Up¥ÁhPo (Multimeters)

       úSôdLeLs:  ClTôPj§u Ø¥®p ¿eLs ùT\ úYi¥V A±Ü §\uLs
       • Up¥ÁhP¬u LhPûUlûT ®Y¬jRp
       • A]Xôd Up¥ÁhPo úYûX ùNnÙm RjÕYjûR ®Y¬jRp
       • Up¥ÁhPo TVuLû[ ®Y¬jRp
       • Up¥ÁhPûW TVuTÓj§ úSo§ûN UôߧûN ªu]ÝjRm Utßm ªuú]ôhPjûR
        A[®Óm Y¯Øû\ûV ®[dÏRp
       • Up¥ÁhPûW TVuTÓj§ ªuRûPûV A[®Óm Y¯Øû\ûV ®[dÏRp
       • ªuÑt±u ªu]ÝjRm, ªuú]ôhPm Utßm ªuRûP B¡VYtû\ A[®Óm
        úTôÕ LûPl©¥dL úYi¥V Øuù]fN¬dûLLû[ ®Y¬jRp.

       LWih, úYôphúP_ó Utßm ùW£vPuv                         A[ÜLû[             A[dL           Up¥ÁhPo
       B¡V êuß A[ÜLû[Ùm JúW LÚ®«p                           TVuTÓ¡\Õ. CRàûPV EPtTϧ«p
       A[dL TVuTÓm ÁhP¬u ùTVo                               Up¥©ú[Vo  (multiplier) Utßm NuhÓdÏ
       Up¥ÁhPo GuTRôÏm.                                     (shunt)      úRûYVô]             ªuRûPLs
       K¬Pj§XõÚkÕ Utù\ôÚ CPj§tÏ GÓjÕf                       ùTôÚjRlThÓs[Õ. CkR ÁhP¬p TX®R
       ùNpXjRdL YûL«p TX A[ÜLû[                             Ñ®hfLû[ ùLôiÓ ÑXTUôL úRûYlTÓm
       A[dÏm T¥VôL CÕ Es[Õ.  ØÝ vúLp                        ÁhP¬u  function Utßm úWugûN úRoÜ
       ¿h£«p  (full scale deflection) CRu ÕpXõVm            ùNnÕ ùLôs[Xôm.
       ±1.5 %. AC ªu]ÝjR úWug¤p  CRu                        £X Up¥ÁhPoL°p CWiÓ Ñ®hLs
       Ïû\kRThN ÕpXõVm 5 K ohms/volts Utßm DC               TVuTÓjRlTÓ¡\Õ. Juß function-ûV úRoÜ
       ªu]ÝjR úWug£p ÕpXõVm 20 K ohms/volts                 ùNnVÜm. Utù\ôuß úWugûV úRoÜ
       BÏm. Ut\ úWugfLû[ Lôh¥Ûm  DC                         ùNnVÜm ùTôÚjRlThÓs[Õ. £X
       Ïû\kR úWug£p CRu ÕpXõVm A§LUôL                       Up¥ÁhPoL°p CkR LôWQj§tÏ Ñ®hf
       CÚdÏm.                                               ûYdLlTÓY§pûX. CRtÏ Uôt\ôL R²VôL
       Fig 1-«p JÚ Up¥ÁhPo Lôi©dLl                          range JqùYôÚ  jacks Utßm úWugdÏ
       ThÓs[Õ.                                              ùTôÚjRlThÓs[Õ. £X Up¥ÁhPoL°p
                                                            CkR LôWQj§tÏ Ñ®hf ûYdLlTÓ§pûX.
        Fig 1
                                                            ªuRûP            CVdLj§tÏ            ÁhP¬u
                                                            EhTϧ«p             ªuLXm            /     ùNp
                                                            ùTôÚjRlThÓs[Õ. DC AmÁhPo Utßm
                                                            úYôph ÁhP¬p TVuTÓjRlTÓm SLÚm
                                                            Lô«p AûUl×  (moving coil system) C§p
                                                            TVuTÓjRlTÓ¡\Õ.
                                                            AC-ûV DC-VôL Uôt\Üm.  ÁhP¬u Esú[
                                                            ùWd¥@ûTVoLs ùTôÚjRlThÓs[Õ.
                                                            Up¥ÁhP¬u TôLeLs (Parts of a multim-
                                                            eter) : JÚ RWUô] Up¥ÁhP¬u TôLeLs
                                                            Fig 2-p LôhPlThÓs[Õ.
                                                            LhÓlTôÓLs  (Controls) :  JÚ  FUNCTION
                                                            Ñ®hf êXUôL ªuú]ôhPm, ªu]ÝjRm
                                                            (AC Utßm DC) Utßm ªuRûP B¡VYtû\
                                                            CkR ÁhPûW TVuTÓj§ A[dLXôm. Fig 3-
                                                            p LôhPlThÓs[ ERôWQj§p Ñ®hf AC
                                                            mA-®p ¨ûX¨ßjRlThÓs[Õ. úWug
                                                            Ñ®hfûV úRoÜ ùNnÕ úRûYVô]
                                                            ªuú]ôhPm, ªu]ÝjRm ApXÕ
       Up¥ÁhP¬u AûUl×  (Construction of a                   ªuRûPûV A[dLXôm.
       multimeter):  JÚ ÁhP¬u JÚ CVdLjûR
       ùLôiÓ úYôph, Km Utßm ªpXõ Bm©Vo