Page 22 - Electrician -1st year -TP - Malayalam
P. 22

72. Practice wiring of hostel and residen-
                                            tial building as per IE rules. (15 Hrs.)

                                          73. Practice wiring of institute and work-
                                            shop as per IE rules. (15 Hrs.)
                                          74. Practice testing / fault detection of
                                            domestic and industrial wiring instal-
                                            lation and repair. (15Hrs.)

        Professional   Plan  and  prepare   75. Prepare pipe earthing and measure   Importance of Earthing.
        Skill 25 Hrs.;  Earthing installa-  earth resistance by earth tester /  Plate earthing and pipe earthing
                      tion.                 megger. (10 Hrs.)                 methods and IEE regulations.
        Professional   (NOS:  PSS/        76. Prepare plate earthing and measure  Earth resistance and earth leakage
        Knowledge     N6002)                earth resistance by earth tester /  circuit breaker. (5 Hrs.)
        07 Hrs.                             megger. (10 Hrs.)
                                          77. Test earth leakage by ELCB and
                                            relay. (5 Hrs.)
        Professional  Plan and execute   78. Install light fitting with reflectors for  Laws of Illuminations.
        Skill 45Hrs.;  electrical illumina-  direct and indirect lighting. (10 Hrs.)  Types of illumination system.
                       tion  system  and   79. Group different wattage of lamps in
                       test.                                                  Illumination factors, intensity of
        Professional   (NOS: N/A)           series for specified voltage. (5 Hrs.)  light.
        Know ledge                       80. Practice installation of various lamps   Type of lamps, advantages/ dis-
        10Hrs.                              e.g. fluorescent tube, HP mercury va-  advantages and their applications.
                                            pour, LP mercury vapour, HP sodium
                                            vapour,  LP  sodium  vapour,  metal  Calculations of lumens and ef-
                                            halide etc. (18 Hrs.)             ficiency. (10 hrs.)
                                         81. Prepare decorative lamp circuit to
                                            produce rotating light effect/running
                                            light effect. (6 Hrs.)
                                         82. Install light fitting for show case light-
                                            ing. (6 Hrs.)

        Professional  Select and perform   83. Practice on various analog and digi-  Classification of electrical instru-
        Skill 50 Hrs.;  measurements us-    tal measuring Instruments. (5 Hrs.)  ments and essential forces re-
                      ing analog / digital   84. Practice on measuring instruments   quired in indicating instruments.
                      instruments  and      in single and three phase circuits   PMMC and Moving iron instru-
        Professional  install/ diagnose     e.g. multi-meter, Wattmeter, Energy   ments.
        Knowledge  smart meters.            meter, Phase sequence meter and
        08 Hrs.                             Frequency meter etc. (12Hrs.)     Measurement of various electrical
                      (NOS:  PSS/                                             parameters using different analog
                      N1707)             85. Measure power in three phase cir-  and digital instruments.
                                            cuit using two wattmeter methods.
                                            (8 Hrs.)                          Measurement of energy in three
                                                                              phase circuit.
                                         86. Measure power factor in three phase
                                            circuit by using power factor meter   Automatic meter reading infra-
                                            and verify the same with voltmeter,   structures and Smart meter.
                                            ammeter and wattmeter readings.   Concept of Prosumer and distrib-
                                            (10Hrs.)                          uted generation.
                                         87. Measure electrical parameters using   Electrical supply requirements of
                                            tong tester in three phase circuits.   smart  meter,  Detecting/clearing
                                            (08Hrs.)                          the tamper notifications of meter.
                                         88. Demonstrate Smart Meter, its physi-  (08 hrs.)
                                            cal components and Communica-
                                            tion components. (03 Hrs.)

                                         89. Perform meter readings, install and
                                            diagnose smart meters. (04 Hrs.)

                                                        (xx)
   17   18   19   20   21   22   23   24   25   26   27