72.Practice wiring of hostel and residen-
                                            tial building as per IE rules. (15 Hrs.)
                                          73.Practice wiring of institute and work-
                                            shop as per IE rules. (15 Hrs.)

                                          74.Practice testing / fault detection of
                                            domestic and industrial wiring instal-
                                            lation and repair. (15Hrs.)

        Professional  Plan and prepare    75.Prepare pipe earthing and measure  Importance of Earthing.
        Skill 25 Hrs.;  Earthing installa-  earth resistance by earth tester / Plate earthing and pipe earthing
                      tion.                 megger. (10 Hrs.)                 methods and IEE regulations.
                      (NOS: PSS/N6002)    76.Prepare plate earthing and measure Earth resistance and earth leakage
        Professional
        Knowledge                           earth resistance by earth tester / circuit breaker. (5 Hrs.)
        07 Hrs.                             megger. (10 Hrs.)
                                          77.Test earth leakage by ELCB and re-
                                            lay. (5 Hrs.)
        Professional   Plan and execute  78.Install light fitting with reflectors for di- Laws of Illuminations.
        Skill 45Hrs.;  electrical illumina-  rect and indirect lighting. (10 Hrs.)  Types of illumination system.
                       tion system and   79.Group different wattage of lamps in
                       test.                                                  Illumination factors, intensity of
        Professional   (NOS: N/A)           series for specified voltage. (5 Hrs.)  light.
        Knowledge                        80.Practice installation of various lamps  Type of lamps, advantages/ disad-
        10Hrs.                              e.g. fluorescent tube, HP mercury  vantages and their applications.
                                            vapour, LP mercury vapour, HP sodium
                                            vapour, LP sodium vapour, metal ha- Calculations of lumens and effi-
                                            lide etc. (18 Hrs.)               ciency. (10 hrs.)
                                         81.Prepare decorative lamp circuit to pro-
                                            duce rotating light effect/running light
                                            effect. (6 Hrs.)
                                         82.Install light fitting for show case light-
                                            ing. (6 Hrs.)

        Professional  Select and perform  83.Practice on various analog and digi-  Classification of electrical instru-
        Skill 50 Hrs.;  measurements us-    tal measuring Instruments. (5 Hrs.)  ments and essential forces required
                      ing analog / digital  84.Practice on measuring instruments  in indicating instruments.
                      instruments and in-   in single and three phase circuits e.g.  PMMC and Moving iron instru-
        Professional  stall/ diagnose       multi-meter, Wattmeter, Energy    ments.
        Knowledge 08  smart meters.         meter, Phase sequence meter and
        Hrs.                                Frequency meter etc. (12Hrs.)     Measurement of various electrical
                      (NOS: PSS/N1707)                                        parameters using different analog
                                         85.Measure power in three phase cir-  and digital instruments.
                                            cuit using two wattmeter methods.
                                            (8 Hrs.)                          Measurement of energy in three
                                                                              phase circuit.
                                         86.Measure power factor in three phase
                                            circuit by using power factor meter  Automatic meter reading infrastruc-
                                            and verify the same with voltmeter,  tures and Smart meter.
                                            ammeter and wattmeter readings.   Concept of Prosumer and distrib-
                                            (10Hrs.)                          uted generation.
                                         87.Measure electrical parameters using  Electrical supply requirements of
                                            tong tester in three phase circuits.  smart meter, Detecting/clearing the
                                            (08Hrs.)                          tamper notifications of meter.  (08

                                         88.Demonstrate Smart Meter, its physi-  hrs.)
                                            cal components and Communication
                                            components. (03 Hrs.)
                                         89.Perform meter readings, install and
                                            diagnose smart meters. (04 Hrs.)

                                                        (xvi)