73.Identify drier and capillary tube  Expansion Valve
                                               used in different cooling
                                               machines. (09 hrs.)             Expansion valve used in
                                                                               domestic refrigeration and air
                                             74.Replace drier and capillary tube  conditioning  systems.
                                               at the time of gas charging     Capillaries, Automatic  and
                                               according to manufacturer’s     Thermostatic Ex. Valves, and
                                               direction. (10 hrs.)            electronic expansion valves.(10
                                                                               hrs..)
        Professional   Perform servicing of  75.Identify and service different  Evaporator
        Skill 16       different evaporator    types of evaporators like plate  Working principle, Function,
        Hrs.;          used in different       and tube type,  Fin andtube     types  of  evaporators  used in
                       appliances.             type,    etc.    fitted  in
        Professional                           refrigerators, Bottle coolers,  refrigerator, water coolers,
        Knowledge                              water cooler, Window and split  bottle coolers, window and split
        05 Hrs.                                                                A.C, Super heating in
                                               AC. (08 hrs.)
                                                                               evaporators, Function of
                                             76.Perform leak test, flush to    accumulator and types.
                                               remove oil by dry nitrogen in   Methods of defrosting.
                                               evaporator. (08 hrs.)           (05 hrs..)
        Professional   Carry out Recovery    77.Identify and explain different  Refrigerant
        Skill 30       and Recycling of        colour code of different type   Classification of refrigerants,
        Hrs.;          Refrigerant used,       refrigerant cylinder like HCFCs  nomenclature of refrigerants
                       alternative of CFC,     (HCFC-22, HCFC-123). HFCs
        Professional                                                           including chemical name and
        Knowledge      HFC re-cover, transfer  (HFC-134a, HFC-32, R- 410A,     formulas,   hydro    chloro
        06 Hrs.        & handing of gas        R-407C and R-404A) and low-     fluorocarbons (HCFCs), hydro
                       cylinders.              Global Warming Potential        fluorocarbons (HFCs) and hydro
                                               (GWP) refrigerants like         fluoroolefins (HFOs), blends of
                                               ammonia, R-290, HFC- 32,        HFCs and blends of HFCs/HFOs.
                                               blends of HFCs (R-410A, R-      Climatic impact of refrigerants:
                                               404A, R-407C etc.) and hydro    Stratospheric ozone depletion,
                                               Fluor olefins (HFOs: HFO-       global warming, mechanism of
                                               1234yf, HFO-1234ze, HFO-        ozone depletion; the Montreal
                                               1233zd, HFO-1336mz), blends     Protocol phase-out schedule of
                                               of HFCs and HFOs. (10 hrs.)
                                                                               ozone  depleting  refrigerants
                                             78.Recover refrigerant from a faulty  (HCFCs) and high global warming
                                               machine. (07 hrs.)              refrigerants (HFCs). Brief
                                                                               introduction of Ozone Depleting
                                             79.Transfer refrigerant from one  Substances (Regulation and
                                               cylinder to another using ice.  Control) Rules, 2000 and its
                                               (04 hrs.)
                                                                               amendments. Introduction of
                                             80.Measure pressure               properties of refrigerants;
                                               andtemperature of refrigerants  environment related properties:
                                               including HCFC-22, ammonia,     Ozone Depleting Potential
                                               R-290, HFC-32, HFC-134a, R-     (ODP), GWP; ODP and
                                               404A, R-407Cand R-410A,         GWP        of        various
                                               HFOs. Identify flammability and  refrigerants,  thermo  chemical
                                               toxicity of A3 and A2L of       properties: flammability and
                                               refrigerants. (09 hrs.)         toxicity of refrigerants, lower
                                                                               flammability limit (LFL) and upper
                                                                               flammability limit of A3 and A2L
                                                                               refrigerants. Thermo physical
                                                                               properties: pressure temperature
                                                                               of different refrigerants.(06 hrs..)









                                                        (xvi)